Category |
Item |
Parameters |
Detection Methods |
|
|
Machine tool accuracy |
Positioning accuracy (X/Y/Z three axes) |
±30μm |
Renishaw laser interferometer, ballbar |
|
|
Repeat positioning accuracy (X/Y/Z three axes) |
±20μm |
|||
|
Working platform flatness |
100μm |
|||
|
X/Y/Z three-axis linear motion |
±20μm/m |
|||
|
Perpendicularity between X-axis and Y-axis |
15μm |
|||
|
Perpendicularity between Z axis and X/Y axis |
20μm |
|||
|
Machine size |
Work schedule |
X axis |
650mm |
Tape measure, operating software display |
|
Y axis |
550mm |
|||
|
Z axis |
10mm |
|||
|
Workbench size |
X direction |
700mm |
||
|
Y direction |
600mm |
|||
|
Machine tool dimensions |
Length |
1700mm |
||
|
Width |
2000mm |
|||
|
Height |
1900mm |
|||
|
Positioning method |
CCD Automatic identification |
±30μm |
Second dimension coordinate measuring machine |
|
|
Laser parameters |
Laser power |
20W |
Laser Power Meter |
|
|
Laser wavelength |
532nm |
Laser Power Meter |
||
|
Cooling method |
Water Cooling |
|
||
|
Processing performance |
Fast moving speed (X/Y axis) |
500mm/s |
Software Display |
|
|
Maximum drilling speed @1.1H |
5 / 9 / 14 mm/s |
Software Display |
||
|
Single processing range |
40×40mm |
Software Display |
||
|
Minimum processing hole diameter |
0.3mm |
Second dimension coordinate measuring machine |
||
|
Processed glass thickness |
≤4mm |
Vernier caliper |
||
|
Processing accuracy |
Collapse |
≤120μm |
Second dimension coordinate measuring machine |
|
|
Square size accuracy |
10μm |
Second dimension coordinate measuring machine |
||
|
True roundness |
15μm |
Ballbar |
||
|
Lubrication system |
Lubrication pump capacity |
1L |
Measuring cup |
|
|
Flow |
120-140cc/min |
Flow Meter |
||
|
Pressure |
1.5-1.7Mpa |
Pressure gauge |
||
|
Machine power |
Total voltage |
AC380V/50Hz |
Multifunctional power meter |
|
|
Total machine power |
4KW |
Multifunctional power meter |
||
|
Compressed gas requirements |
Pressure |
0.5Mpa-0.7Mpa |
Pressure gauge |
|
|
Flow |
150L/min |
Flow Meter |
||
|
Vacuum requirements |
Pressure |
-0.06Mpa以上 |
Vacuum pressure gauge |
|
|
Flow |
100L/min |
Flow Meter |
||
|
Environmental requirements |
Temperature |
+15℃~+30℃ |
Thermometer and Hygrometer |
|
|
Humidity |
<50% |
Thermometer and Hygrometer |
||
|
System requirements |
Control Software |
windowsXP |
System Display |
|
|
Machine weight |
Machine weight |
2000KG |
Weighbridge |
|
|
No |
Parts Name |
Model Specifications |
Origin/Manufacturer |
Memo |
|
1 |
Control system |
CCD automatic identification and positioning |
Wuhan |
Genuine |
|
2 |
Operating system |
Window XP |
Microsoft |
Professional Edition |
|
3 |
Industrial computer |
Customized |
Domestic |
Industrial Grade |
|
4 |
CCD camera |
300 W |
Korea/MV |
Original Imported |
|
5 |
X/Y axis linear guide |
P-level |
Taiwan/HIWIN |
Original Imported |
|
6 |
Z axis linear guide |
P-level |
Taiwan/HIWIN |
Original Imported |
|
7 |
Servo motor 750W |
A5 series (optional linear motor) |
Japan/Panasonic |
Original Imported |
|
8 |
Servo motor 750W |
A5 series (optional linear motor) |
Japan/Panasonic |
Original Imported |
|
9 |
Z axis servo drive 200W |
A5 series (optional) |
Japan/Panasonic |
Industrial Grade |
|
10 |
Manual oiler |
Customized |
Domestic |
Industrial Grade |
|
11 |
Integrated laser |
Customized |
Wuhan |
Industrial Grade |
|
12 |
Laser chiller |
Customized |
Wuhan |
Original Imported |
|
13 |
Optical path system |
Customized |
Germany |
Original Imported |
|
14 |
Focusing system |
650×550 Customized |
Germany |
Industrial Grade |
|
15 |
Working platform |
Granite |
Wuhan |
Industrial Grade |
|
16 |
Marble |
Customized |
Shandong |
Industrial Grade |
|
17 |
Dust removal system |
Customized |
Wuhan |
Industrial Grade |
|
18 |
Waste collection system |
Photoelectricity |
Wuhan |
Industrial Grade |
|
19 |
Proximity switch |
Flexible multi-core wire |
Japan/Omron |
Original Imported |
|
20 |
Flexible cable |
Solenoid valve |
Germany/Lamp |
Original Imported |
|
21 |
Pneumatic components |
CCD automatic identification and positioning |
AirTAC |
Industrial Grade |
The company introduced Renishaw laser interferometers from the United States. Among its peers, our company is the first to own this high-end testing equipment to ensure machine accuracy.
The Israeli OPHIR laser power meter introduced by the company has a detection accuracy of 0.01 and can accurately measure and detect laser stability.
The company has introduced the American Tektronix laser pulse width detector to accurately measure the laser pulse width data and judge the laser processing effect and its practicality.
|
No |
Parts Name |
Qty |
Memo |
|
1 |
Random tool box |
1 |
Contains common tools |
|
2 |
Optical cotton wool |
1 |
For cleaning optical lenses |
|
3 |
Lens cleaning paper |
1 |
|
|
4 |
Laser protective glasses |
1 |
PROFESSIONAL LASER